This set of Mechanical Measurements Multiple Choice Questions & Answers (MCQs) focuses on Mechanical Measurements Set 7
Q1 | Under force-voltage analogy, velocity is considered as analogous to
- Resistance
- Charge
- Current
- Magnetic flux
- Inductance
Q2 | Which of the following is an electric tachometer?
- Stroboscopic tachometer
- Eddy current tachometer
- Drag type tachometer
- Ignition type tachometer
- All of the above
Q3 | Phosphor bronze Bourdon tube can be used of pressures upto
- 15 kg/cm2
- 10 kg/cm2
- 70 kg/cm2
- 5 kg/cm2
- 170 kg/cm2
Q4 | The thermometer is calibrated 150?C to 200?C. The accuracy is specified within
- 0.5?C
- 1?C
- ? 1?C
Q5 | Which of the following is not an elecment of electro-pneumatic pressure transmitter?
- LVDT
- Bellows
- Opamp
- Flapper nozzle mechanism
- All of the above
Q6 | In case of obstruction meters used for flow measurement, pressure recovery is maximum in the case of
- venturi
- flow nozzle
- orifice
- None of the above
- Any of the above
Q7 | A transducer that converts the input physical phenomenon into an electrical output in the form of pulses is known as
- Secondary transducer
- Analogy transducer
- Digital transducer
- Tuned transistor
- None of the above
Q8 | Which of the following statement is wrong for thermocouple measuring instruments?
- They read average values
- When calibrated on dc they cannot be used for ac signals
- They cannot take overheads
- Their calibration dies not change with time or temperature
- They read rms values
Q9 | In a load cell, strain gauge acts as a
- Protective device
- Comparator
- Primary transducer
- Secondary transducer
- None of the above
Q10 | Which of the following device can be used to measure blow of air around an aeroplane?
- Rotameter
- Venturimeter
- Manometer
- Anemometer
- Orifice
Q11 | Under force-current analogy, mass is considered analogous to
- Reciprocal of resistance
- Reciprocal of capacitance
- Resistance
- Current
- Capacitance
Q12 | Which of the following magnetic material has highest coercive force?
- Tungsten steel
- Dead mild steel
- Alcomax
- Carbon steel
- Cobalt steel
Q13 | Metres A and B require 50 mA and mA respectively to give full scale deflection. It can be concluded that
- A is more sensitive as compared to B
- B is more sensitive as compared to B
- A has wider range than B
- B has better damping as compared to A
- None of the above
Q14 | The accuracy of a 0 - 10 mV meter is
- 9 mV
- Either 9 mV or 10 mV
- Either 9 mV or 11 mV
- 11 mV
- More than 11 mV
Q15 | The gauge factor for doped crystal is in the range
- 100 to 5000
- 2 to 20
- 1 to 2
- 0.5 to 1
- 20 to 50
Q16 | Although semi-conductor strain gauges have high gauge factor still these are not preferred due to
- Difficulties in connections and high cost of auxiliary equipment
- Small size and high cost
- Small size and high cost
- Non-linearity
- Non-linearity and sensitivity to temperature fluctuations
Q17 | A strain gauge material should have low
- Gauge factor
- Sensitivity
- Resistance temperature coefficient
- All of the above
- 100 to 5000
Q18 | The statement 'the most probable value of an observed quantity available from a given lot of observations is the one for which the sum of the square of error is a minimum" is known as law of
- squared errors
- Pythagorous theorem
- least squares
- None of the above
- Any of the above
Q19 | A strain gage material should have low
- gage factor
- strain sensitivity
- resistance temperature coefficient
- None of the above
- Any of the above
Q20 | The least count of a vernier caliper used in industries is generally
- 0.001 mm
- 1 mm
- 0.02 mm
- None of the above
- None of the above
Q21 | The value of permissible error depends upon
- The scale
- The instrument available
- Class of work
- All of the above
- None of the above
Q22 | Stainless steel Bourdon tube pressure gauge joints are usually
- Welded
- Adhesive jointed
- Soldered
- Brazed
- Screwed
Q23 | Which of the following is generally not used as a thermocouple material?
- Platinum - Rhodium
- Chromel - Alumel
- Gold - Silver
- Chromel - Copper
- None of the above
Q24 | A degital thermometer has 3
- 1.000?C
- 1.001?C
- 1.999?C
- 0.999?C
- None of the above
Q25 | A geodimeter is used for the measurements of
- Distances
- Volumes
- Angles
- Bearings of a point
- Areas