On This Page
This set of Mechanical Measurements Multiple Choice Questions & Answers (MCQs) focuses on Mechanical Measurements Set 4
Q1 | The errors which form inexperience of the observer are known as
- Personal errors
- Mistakes
- Training errors
- Accidental errors
- Handling errors
Q2 | The duty cycle of a pulse of width 2 micro sec and repetition frequency 4 kHz is
- 0.5
- 0.008
- 0.05
- 0.0006
- 0.00008
Q3 | Which of the following device cannot be used to measure pressure?
- Pirani gauge
- Strain gauge
- LVDT
- Manometer
- Bolometer
Q4 | If a measuring tape is too long as compared to standard, the error will be known as
- Manufacturing error
- Natural error
- Superficial error
- Personal error
- Instrumental error
Q5 | An iron-constantan thermocouple can be used for the temperature
- ?175?C to 900?C
- ?250?V to 1500?C
- ?373?C to 1800?C
- 0?C to 2500?C
- 0?C to 600?C
Q6 | For measuring the temperature of a boiler furnace which one of the following is the appropriate thermometer?
- Optical pyrometer
- Bimetallic thermometer
- Thermocouple
- Resistance thermometer
- Any of the above
Q7 | The resistance of a strain gauge should be high
- To increase sensitivity
- To reduce hysteresis effect
- To swamp out the effects of variations of resistance in other parts of the bridge
- None of the above
- 100 to 5000
Q8 | Which of the following transducer is used to translate linear motion into electrical signals?
- Bourdons tube
- LVDT
- Bellows
- Strain gauge
- Thermistor
Q9 | If an error under the same conditions will always be of the same size and sign, it is known as
- Training errors
- Systematic errors
- Cumulative error
- Either of (A) and (B) above
- Either of (B) and (C) above
Q10 | The degree of fementation in brewing pressure can be measured by
- Bolometer
- Conductivity meter
- pH meter
- Smoke meter
- Turbidity meter
Q11 | Which of the following will be the most alkaline solution?
- pH 4
- pH 1
- pH 7
- pH 10
- pH 14
Q12 | McLeod gage is used to measure
- pressure
- vacuum
- Flow rate
- None of the above
- Any of the above
Q13 | The standard oxygen point temperature is
- 182.97?C
- ?213.99?C
- 163.45?C
- ?182.27?C
- 0?C
Q14 | In measurements using two strain gauges, the purpose of dummy strain gauge is
- To unllify the errors due to temperature
- Improve stability of the measuring system
- Measure lateral strain
- Increase the sensitivity of measuring system
- None of the above
Q15 | If a steam pressure of 10 kg/cm2 is to be measured, the range of pressure gauge should be
- 0 to 100 kg kg/cm2
- 0 to 10 kg kg/cm2
- 0 to 20 kg kg/cm2
- ?10 kg/cm2 to + 10 kg kg/cm2
- 5 to 11 kg kg/cm2
Q16 | Which of the following can be used as thermal detector?
- Thermistor
- Pyrometer
- Thermocouple
- Resistance thermometer
- Any of the above
Q17 | The electricl resistarice of a wire is
- Directly proportional to diameter and inversely proportional to length
- Directly proportional to length and inversely proportional to diameter
- Directly proportional to length and diameter
- Inversely proportional to resistance and length
- None of the above
Q18 | The joints of a phosphor-bronze Bourdon tubes are
- Welded
- Brazed
- Soldered
- Jointed by adhesives
- Screwed
Q19 | Which of the following temperature is highest.
- Melting point of gold
- melting point of silver
- melting point of steel
- None of the above
- Any of the above
Q20 | Which of the following device can be used to give an indication for temperature changes?
- Thermistor
- Bourden gauge
- Transistor
- Thermocouple
- LED
Q21 | A simple ac amplifier may be used to amplify dc input through use of an additional circuit component known as
- tuned amplifier
- carrier
- chopper
- None of the above
- Any of the above
Q22 | Positive displacement flow meters are
- variable area flow meter
- differential pressure flow meter
- quantity flow meter
- None of the above
- Any of the above
Q23 | Which of the following meter is preferred for the measurement of pressure in a steam condenser?
- Manometer
- Kentometer
- Pitot tube
- Mcleod gauge
- None of the above
Q24 | A rotameter is used to measure
- velocity of liquids
- pressure of gases
- specific gravity of liquids
- None of the above
- Any of the above
Q25 | Which of the following transducer is preferred for measurements involving sound?
- Piezoelectric pick up
- Photoemissive cell
- Volt box
- Kundt's tube
- Thermocouple