Switch Gear And Protection Set 4

On This Page

This set of Switch Gear and Protection Multiple Choice Questions & Answers (MCQs) focuses on Switch Gear And Protection Set 4

Q1 | Which of the following circuit breakers has high reliability andminimum maintenance ?
  • Air blast circuit breakers
  • Circuit breaker with SF6 gas
  • Vacuum circuit breakers
  • Oil circuit breakers
Q2 | Arc in a circuit breaker is interrupted at
  • zero current
  • maximum current
  • minimum voltage
  • maximum voltage
Q3 | transmission line has reflection coefficient as one.
  • Open circuit
  • Short-circuit
  • Long
  • None of the above
Q4 | What will be the reflection co-efficient of the wave of load connected to transmission line if surge impedance of the line is equal to load ?
  • Zero
  • Unity
  • Infinity
  • None of the above
Q5 | The inverse definite mean time relays are used for over current and earth fault protection of transformer against
  • heavy loads
  • internal short-circuits
  • external short-circuits
  • all of the above
Q6 | Over voltage protection is recommended for
  • hydro-electric generators
  • steam turbine generators
  • gas turbine generators
  • all of the above
Q7 | Air blast circuit breakers for 400 kV power system are designed tooperate in
  • 100 microsecond
  • 50 millisecond
  • 0.5 sec
  • 0.1 sec
Q8 | Overfluxing protection is recommended for
  • distribution transformer
  • generator transformer of the power plant
  • auto-transformer of the power plant
  • station tr
Q9 | Series capacitors are used to
  • compensate for line inductive reactance
  • compensate for line capacitive reactance
  • improve line voltage
  • none of the above
Q10 | Admittance relay is _______ relay.
  • impedance
  • directional
  • non-directional
  • none of the above
Q11 | The material used for fuse must have
  • low melting point and high specific resistance
  • low melting point and -low specific resistance
  • high melting point and low specific resistance
  • low melting point and any specific resistance
Q12 | If the fault occurs near the impedance relay, the VII ratio will be
  • constant for all distances
  • lower than that of if fault occurs away from the relay
  • higher than that of if fault occurs away from the relay
  • none of the above
Q13 | The torque produced in induction type relay (shaded pole structure) is
  • inversely proportional to the current
  • inversely proportional to the square of the current
  • proportional to the current
  • proportional to square of the current
Q14 | The steady state stability of the power system can be increased by
  • connecting lines in parallel
  • connecting lines in series
  • using machines of high impedance
  • reducing the excitation of machines
Q15 | The inductive interference between power and communication linecan be minimized by
  • transposition of the power line
  • transposition of the communication line
  • both (a) and (b)
  • increasing the distance between the conductors
Q16 | The power loss is an important factor for the design of
  • transmission line
  • motor
  • generator
  • feeder
Q17 | A fuse is connected
  • in series with circuit
  • in parallel with circuit
  • either in series or in parallel with circuit
  • none of the above
Q18 | H.R.C. fuse, as compared to a rewirable fuse, has
  • no ageing effect
  • high speed of operation
  • high rupturing capacity
  • all of the above
Q19 | The fuse rating is expressed in terms of
  • current
  • voltage
  • VAR
  • kVA
Q20 | The fuse blows off by
  • burning
  • arcing
  • melting
  • none of the above
Q21 | On which of the following effects of electric current a fuse operates ?
  • Photoelectric effect
  • Electrostatic effect
  • Heating effect
  • Magnetic effect
Q22 | An isolator is installed
  • to operate the relay of circuit breaker
  • as a substitute for circuit breaker
  • always independent of the position of circuit breaker
  • generally on both sides of a circuit breaker
Q23 | A fuse in a motor circuit provides protection against
  • overload
  • short-circuit and overload
  • open circuit, short-circuit and overload
  • none of the above
Q24 | Protection by fuses is generally not used beyond
  • 20 A
  • 50 A
  • 100 A
  • 200 A
Q25 | A fuse is never inserted in
  • neutral wire
  • negative of D.C. circuit
  • positive of D.C. circuit
  • phase dine