Information Retrival Techniques Set 1

On This Page

This set of Information Retrival Techniques Multiple Choice Questions & Answers (MCQs) focuses on Information Retrival Techniques Set 1

Q1 | Which of the following is golden rule for interface design?
  • place the user in control
  • reduce the user’s memory load
  • make the interface consistent
  • all of the mentioned
Q2 | Which of the following is not a design principle that allow the user to maintain control?
  • provide for flexible interaction
  • allow user interaction to be interrupt-able and undo-able
  • show technical internals from the casual user
  • design for direct interaction with objects that appear on the screen
Q3 | Which of the following is not a user interface design process?
  • user, task, and environment analysis and modeling
  • interface design
  • knowledgeable, frequent users
  • interface validation
Q4 | When users are involved in complex tasks, the demand on                      can be significant.
  • short-term memory
  • shortcuts
  • objects that appear on the screen
  • all of the mentioned
Q5 | Which of the following option is not considered by the Interface design?
  • the design of interfaces between software components
  • the design of interfaces between the software and human producers and consumers of information
  • the design of the interface between two computers
  • all of the mentioned
Q6 | A software might allow a user to interact via
  • keyboard commands
  • mouse movement
  • voice recognition commands
  • all of the mentioned
Q7 | What incorporates data, architectural, interface, and procedural representations of the software?
  • design model
  • user’s model
  • mental image
  • system image
Q8 | What establishes the profile of end-users of the system?
  • design model
  • user’s model
  • mental image
  • system image
Q9 | What combines the outward manifestation of the computer-based system , coupled with all supporting information that describe system syntax and semantics?
  • mental image
  • interface design
  • system image
  • interface validation
Q10 | Which of the following is used to access the database server at the time of executing the program and get the data from the server accordingly?
  • embedded sql
  • dynamic sql
  • sql declarations
  • sql data analysis
Q11 | Which of the following header must be included in java program to establish database connectivity using JDBC ?
  • import java.sql.*;
  • import java.sql.odbc.jdbc.*;
  • import java.jdbc.*;
  • import java.sql.jdbc.*;
Q12 | Which of the following invokes functions in sql?
  • prepared statements
  • connection statement
  • callable statements
  • all of the mentioned
Q13 | Which of the following function is used to find the column count of the particular resultset?
  • getmetadata()
  • metadata()
  • getcolumn()
  • get count()
Q14 | Which of the following is a following statement is a prepared statements?
  • insert into department values(?,?,?)
  • insert into department values(x,x,x)
  • sqlsetconnectoption(conn, sql autocommit, 0)
  • sqltransact(conn, sql rollback)
Q15 | Which of the following is used as the embedded SQL in COBOL?
  • exec sql ;
  • exec sql end-exec
  • exec sql
  • exec sql end exec;
Q16 | Which of the following is used to distinguish the variables in SQL from the host language variables?
  • .
  • :
  • ,
Q17 | Which of the following is used to access large objects from a database ?
  • setblob()
  • getblob()
  • getclob()
  • all of the mentioned
Q18 | Which of the following is not a source used in Mid Infrared Spectrophotometer?
  • nernst glower
  • high pressure mercury arc lamp
  • globar
  • nichrome wire
Q19 | Which of the following is the wave number of near infrared spectrometer?
  • 4000 – 200 cm-1
  • 200 – 10 cm-1
  • 12500 – 4000 cm-1
  • 50 – 1000 cm-1
Q20 | Which of the following options are correct in terms of wavelength for the different types of IR spectrometer?
  • near ir: 0.8 – 2.5 mm
  • mid ir: 0.8 – 2.5 mm
  • far ir: 2.5 – 50 mm
  • mid ir: 50 – 100 mm
Q21 | Which of the following is not a composition of Nernst glower or Nernst filament?
  • oxides of zirconium
  • oxides of barium
  • oxides of yitrium
  • oxides of thorium
Q22 | What is the composition of Globar rod which is used as a source in Mid IR spectroscopy?
  • silicon carbide
  • silver chloride
  • silicon dioxide
  • silver carbide
Q23 | Bolometer, a type of detector, is also known as                        
  • resistance temperature detector (rtd)
  • thermistor
  • thermocouple
  • golay cell
Q24 | Which of the following is not a technique for preparing solid samples in IR spectroscopy?
  • solids run in solution
  • mull technique
  • solid films
  • thin films
Q25 | Which of the following is not used as pyroelectric material used in pyroelectric transducers in Infrared spectroscopy?
  • triglycine sulphate
  • deutrated triglycine sulphate
  • some polymers
  • tetraglycine sulphate