Metrology And Measurements Set 12

On This Page

This set of Metrology and Measurements Multiple Choice Questions & Answers (MCQs) focuses on Metrology And Measurements Set 12

Q1 | Which of the following is the best for the examination of surface finish?
  • touch inspection
  • visual inspection
  • scratch inspection
  • microscopic inspection
Q2 | Which of the following material is not used for rubbing on the surface to be inspected in scratch inspection?
  • softer material
  • hard material
  • plastic
  • lead babbitt
Q3 | What is the limitation of microscopic inspection to check surface finish?
  • an average value is needed
  • small portion of surface can be detected at a time
  • a master finish surface is also needed
  • it is necessary to inspect whole surface together
Q4 | In the method of microscopic inspection what is the angle of beam light with the work?
  • 200
  • 300
  • 600
  • 900
Q5 | Which of the following is true for a method of measurement of surface finish with surface photographs?
  • different type of illumination is needed
  • no effect of type of illumination
  • same type of illumination is needed
  • monochromatic light is needed
Q6 | In case of vertical illumination in measuring surface finish with surface photographs, which will appear as bright area?
  • flat portion
  • scratch
  • irregularity
  • hills
Q7 | Which of the following method use pendulum in measuring the surface finish?
  • micro interferometer
  • wallace surface dynamometer
  • reflected light intensity method
  • microscopic inspection
Q8 | Which of the following is not true for the method of measurement of surface finish by micro interferometer?
  • optical flat is used
  • monochromatic source of light is used
  • depth of defect can’t be measured
  • interference lines plays an important role in identification of the defect
Q9 | Which of the following is the direct measure of surface finish in Wallace surface dynamometer?
  • time of swing
  • angle of swing
  • length of swing
  • height of swing
Q10 | Which of the following is a destructive method in measuring surface finish?
  • gloss measurement
  • taper sectioning
  • diffraction technique
  • micro interferometer
Q11 | In which type of system does power transmission takes place through compressed air?
  • fluid power system
  • hydraulic system
  • pneumatic system
  • stepper motors
Q12 | The compressed air flows to the actuator through          
  • pipes and valves
  • shafts
  • motors
  • flow control valve
Q13 | The compressed air is delivered to the pneumatic system through the air compressor.
  • true
  • false
Q14 | What is the function of the air dryer?
  • removes dirt
  • removes moisture
  • controls the rate of flow
  • controls the pressure
Q15 | Which part of the Pneumatic system stores the compressed air?
  • air dryer
  • air compressor
  • air receiver tank
  • air lubricator
Q16 | Which type of pumps can give discharge even at high pressure?
  • multistage pumps
  • monoblock pumps
  • rotary pumps
  • single stage pumps
Q17 | Which type of component in the hydraulic system supports less vibration and noise?
  • flow control valve
  • oil reservoir
  • rotatory pumps
  • pressure gauge
Q18 | Hydraulic systems are slower in operation.
  • true
  • false
Q19 | What prevents the leakage of oil inside an unbalanced vane pump?
  • vanes
  • cylindrical rotor
  • screw
  • difference between the pressure of inlet and outlet
Q20 | Which among the following are not the main selection criteria for selection of hydraulic pumps?
  • discharge
  • pressure
  • speed
  • weight
Q21 | Which is the cheapest device for measuring flow / discharge rate.
  • venturimeter
  • pitot tube
  • orificemeter
  • none of the mentioned
Q22 | The principle of Orificemeter is same as that of Venturimeter.
  • true
  • false
Q23 | What is the relationship between Orificemeter diameter and pipe diameter
  • orificemeter diameter is 0.5 times the pipe diameter
  • orificemeter diameter is one third times the pipe diameter
  • orificemeter diameter is one fourth times the pipe diameter
  • orificemeter diameter is equal to the pipe diameter
Q24 | The Orificemeter readings are more accurate than Venturimeter.
  • true
  • false
Q25 | The Orificemeter readings are more accurate than Pitot tube readings.
  • true
  • false