On This Page
This set of Electromagnetic Interference Multiple Choice Questions & Answers (MCQs) focuses on Electromagnetic Interference Set 1
Q1 | Moving Iron instruments can be used on:
- ac and dc both
- ac only
- dc only
- none of the above
Q2 | In spring control instruments, controlling torque:
- can be adjusted easily
- cannot be adjusted easily
- remains the same
- varies with the load
Q3 | Chemical effect is used for the operation of:
- voltmeter
- ammeter
- ampere hour meter
- kwh meter
Q4 | The deflection torque can be produced by:
- gravity control
- spring control
- air friction
- magneitcally
Q5 | Moving coil instruments are:
- permanent magnet type
- dynamometer type
- induction type
- permanent magnet and dynamometer type
Q6 | For increasing the range of an ammeter, connect:
- a high value resistance in series with the ammeter coil
- a high value resistance in parallel with the ammeter coil
- a low value resistance in parallel with the ammeter coil
- a low value resistance in series with the ammeter coil
Q7 | A galvanometer can be used for measuring current and voltage of a circuitby:
- shunt only
- connecting high value of resistance in series only
- shunt for measuring current and high resistance in series for voltage
- without shunt and series resistance
Q8 | The energy consumption of MI instrument as compared to MC instrument is:
- same
- more
- less
- very small
Q9 | An ammeter requires a change of 4A in its coil to produce a pointer deflectionof 8mm then its sensitivity is
- 2.5 mm/a
- 2.0 mm/a
- 0.5 mm/a
- none of the above
Q10 | Electrostatic type instruments are mainly used for measurement of
- heavy currents
- low currents
- low voltages
- high voltages
Q11 | Measurement range of a voltmeter can be extended by using:
- high current resistance
- high series resistance
- low shunt resistance
- low series resistance
Q12 | Which of the following voltmeter have least power consumption:
- moving iron
- hot-wire
- electrostatic
- induction type
Q13 | Which of the following instruments have least torque/weight ratio:
- dynamometer type
- pmmc
- attraction type moving iron
- repulsion type moving iron
Q14 | Fluid friction damping can be used in
- horizontally mounted instruments
- vertically mounted instruments
- both horizontally mounted instruments and vertically mounted instruments
- none of the above
Q15 | The ratio and phase angle errors in potential transformer may be reduced by
- increasing the exciting current
- increasing the resistance and leakage reactance in the transformer
- by not employing turns compensation
- none of the above
Q16 | A voltmeter should have
- . low internal resistance
- . high internal resistance
- . electrostatic plates
- . a sensitive amplifier
Q17 | The major advantage of electromagnet type meter over a permanent magnetmeter is
- . the electromagnet meter costs much less
- the permanent magnet meter has a more sluggish coil
- . the electromagnet meter need not be aligned with the earth’s magnetic field
- . the electromagnet meter is more rugged
Q18 | The change in the direction of a compass needle, when a current carrying wireis brought near, is called
- . electromagnetic deflection
- . electroscopic force
- magnetic force
- . electrostatic force
Q19 | The use of _____ instruments is merely confined within laboratories asstandardizing instruments.
- absolute
- indicating
- recording
- integrating
Q20 | Which of the following instruments indicate the instantaneous value of theelectrical quantity being measured at the time at which it is being measured ?
- absolute instruments
- indicating instruments
- recording instruments
- integrating instruments
Q21 | _____ instruments are those which measure the total quantity of electricitydelivered in a particular time.
- absolute
- indicating
- recording
- integrating
Q22 | Which of the following are integrating instruments ?
- ammeters
- voltmeters
- wattmeters
- ampere-hour and watt-hour meters
Q23 | Which of the following essential features is possessed by an indicatinginstrument ?
- deflecting device
- controlling device
- damping device
- all of the above
Q24 | A _____ device prevents the oscillation of the moving system andenables the latter to reach its final position quickly
- deflecting
- controlling
- damping
- any of the above
Q25 | The spring material used in a spring control device should have thefollowing property.
- should be non-magnetic
- most be of low temperature co-efficient
- should have low specific resistance
- all of the above