antiseptic

A chemical agent used to inhibit the growth of microorganisms on skin and mucous membranes is a/an:

disinfection

The process of destroying microorganisms on inanimate (nonliving) objects is:

terminal sterilization

The procedure for destroying pathogens at the end of the procedure is:

saturated steam under pressure

The safest, most practical means for sterilizing heat- and moisture-stable items is:

250 degrees Fahrenheit (121 degree Celcius)

The minimal temperature required to kill bacterial spores is:

prevacuum

The Bowie-Dick test must be run daily in which of the following types of sterilizers?

gravity displacement

Sterilizer that requires a drying cycle:

ethylene oxide gas

Aeration is essential following sterilization by:

3 minutes

In the middle of the surgical procedure a critical stainless steel instrument is contaminated and there is no sterile replacement. Recommended time to flash a small number of instruments is?

biological

The most reliable means of monitoring the effectiveness of the sterilizer that ensures sterilization parameters have been met is:

left open and placed on a rack

When packaging instruments for sterilization instruments should be:

behind packs with older dates

When storing sterile packs, you should place them:

critical

Items that contact sterile tissue and must be sterilized are considered:

rinse immediately before putting in the germicide

When disinfecting instruments for use, you would do all of the following except:

isopropyl alcohol

The disinfectant that should not be used on lensed instruments due to the potential for loosening the "cement" around the lens is:

cleaned up immediately

Spillage of blood that occurs during surgery should be:

maintain positve pressure

The purpose of keeping doors to the operating room closed is to:

remove gross soil and transient microorganisms

The purpose of washing the hands prior to the surgical scrub is to:

recap the remaining portion of the sterile saline for dispensing later during the procedure

When dispensing sterile items to a sterile field, the circulator WOULD NOT:

ensure that wrapper tails are properly secured

When dispensing sterile items to a sterile field, the ciruculator WOULD:

remain with the sterile field until further notified

The scrub has completed the sterile setup when notified that the surgeon will be 30 minutes late. He or she WOULD:

the degree of micobial contamination

Bioburden refers to:

terminal disinfection and sterilization

Procedures performed at the end of a surgical case to protect the health care worker who will be handling the surgical instruments in the sterile processing department are known as:

27 psi

If the temperature on the steam sterilizer reads 270 degrees Fahrenheit, what sould the pressure reading be?