bite registration and occlusal registration
The centric relationship of the upper and lower arches is recorded in the
adhesive
A smooth impression tray is coated with a(n) ____________ before the final impression material is placed in the tray.
syringe-type material
In terms of a final impression, wash is a term used to describe the
extruded, keeping the tip in the material
To avoid air bubbles in a final impression, the heavy body material is
vinyl
The gloves that must be worn when kneading silicone putty for an impression are
addition
Polysiloxane is a type of ____________ silicone impression material.
custom tray, mouth guard and night guard vital bleaching tray
The vacuum former is used to create a
closed
In the __________ bite registration technique, the patient is instructed to close his or her teeth together before the impression material is placed
preliminary impressions, final impressions, and laboratory cases
Gloves must be worn when handling
the syringe-type material is placed around the tooth
In a two-step impression technique, before seating the heavy body impression material,
painted with an adhesive substance
An impression tray with a smooth surface must be _________________ before use
within 15 minutes
The final cure of an elastomeric impression material can occur
as it moves through the mixing tip
When an extruder is used, the impression material is mixed
the same type of impression material
The tubes of catalyst and base are interchangeable if they are
polysulfide
The impression material that has a very strong odor and will permanently stain clothing is
stops
To prevent a custom tray from seating too far on the arch, _______ are created.
faster
When mixing an alginate product, the warmer the water is, the ______ the set will be.
three
A maxillary alginate impression usually requires ____ scoops of powder and three measures of water.
2 minutes
Normal-set alginate has a working time of
absorbs water
If stored in water, an alginate impression