Physics Ch 5 and 6 Fall 2012 review

x-ray tube, operating console, high voltage generator

Name the 3 principle parts of an x-ray imaging system:

low

Operating circuits are:

autotransformer

1st component of circuit to get power is:

1 coil

How many windings are in the autotransformer?

electrons boiled off (mA)

Thermal ionic determines:

electronic

Accurate type of timer:

when IR has received required radiation intensity

When does AEC terminate exposure?

lowest time highest mA

mAs gives:

500-1000 time

Step up transformer increases voltage by:

cathode to anode

Diode flows from:

rectifier, transformer, filament

High voltage contains__________, ____________, __________.

amplitude

Difference in primary and secondary waves?

solid state

Newer rectifiers are:

Positive only

Half wave rectifiers, when current flow through tube?

360 pulses

Full wave, 3 pulse unit, how many pulses?

high frequency

What type of machine is voltage across the tube constant?

High frequency

What type of machine is used for Mammo?

self 100%, half wave 100%, full wave 100%, 3 phase 6 pulse 14%, 3 phase 12 pulse 4%, 3 phase high frequency >1

List the voltage ripple

single phase

Which generator has lowest power rating?

Arm, protective housing, glass envelope

External parts x-ray tube:

Arches

Tube that ages and has tungsten. What happens?

Negative, Positive

Cathode is _______, Anode is _______.

Tungsten vaporizes

Most common cause of tube failure?

space cloud (charge) of electrons

Thermonic creates:

Magnetic field

Rotating anode turns by:

Tungsten

Target is coated with____________.

filiament

Source of radiation in x-ray tube is:

decreases it

Decrease focal spot size, tube angle

10,000 rpm

High capacity tube rotates:

Heel affect

Intensity of beam, lower on anode and:

cathode

The _______ is on thicker part of patient.

long exposure time

Tube failure occurs because of _____ ______ _______.

1-2cm

Approx. how long is the filament _________.

2 filaments

Dual focus tube has _________

kVp, mA, max time

Each tube has a chart showing____, ___, _________

stators

Outside glass envelope is _____________.

rebounding electrons

All focus radiation is produced from ________ __________.

anode angle

Heel effect is caused by ______ _______

smaller

Effect focal spot is:

single excessive exposure

Cracking of anode is:

In the filament

Where is the step down transformer located?

kVp x mA x s= HU

Heat Unit Formula
1 phase

kVp x mA x s x 1.35 = HU

Heat Unit Formula
3 phase 6 pulse

kVp x mA x s x 1.41 = HU

Heat Unit Formula
3phase 12 pulse

kVp x mA x s x 1.45 = HU

Heat Unit Formula
High Frequency

Diode

A diagnostic x-ray tube is an example of a: