What is the difference between the Oxygen we breath and the ozone in the earths stratosphere
Ozone is a form of oxygen, with each molecule consisting of three atoms of oxygen O3 , The oxygen we breath contains two atoms, O2
Describe the difference between good and bad ozone
Good Ozone like the stratosphere protects the earth from harmful ultraviolet rays from the sun, Bad Ozone, Like the Troposphere is considered unwanted ozone because it is a pollutant .
Explain ozone depletion resulting from CFC molecules in the air
Once a CFC molecule is in the stratosphere , Ultraviolet radiation will break off a chlorine atom ( Cl ) from the CFC or HCFC molecule. The chlorine atom can destroy up to 100,000 ozone molecules. The depletion of Ozone lets more UV-B radiation reach the
Which refrigerants have a 0 ODP
HFC's and HC have an ozone depletion Potential of 0
What is Global Warming
Global Warming is the increase in the natural greenhouse effect that leads to heating of the earth
Which refrigerants contribute to global warming
All refrigerants contribute to global warming; only some do it indirect like HFC's and HC's whereas other CFC's and HCFC's contribute directly
What is a GWP
GWP's are given to refrigerant that cause a direct effect of global warming, chemicals that are emitted directly into the atmosphere. Direct effects of global warming are measured by comparing them to CO2, which has an GWP of 1
What is The difference between an ODP and GWP
The difference between an ODP and GWP is: Not every refrigerant has an ODP, The ODP is a number given to a refrigerant that says how strong a refrigerant causes ozone depletion in the stratosphere, whereas all refrigerant have a GWP, CFC HCFC and HFC as w
What is direct and indirect cause of global warming
Direct global warming is the effect cause by a refrigerant leaking to the environment which gets caught in the lower atmosphere and causes a greenhouse effect where as indirect global warming is cause by the refrigerant leak causing longer system run time
What measurment or index takes ito consideration
a. The total equivalent warming impact (TEWI)
b. greenhouse effect number
c. global warming number
d. greenhouse effect index
a. the total equivalent warming impact (TEWI)
What is a CFC, HCFC ,HFC, HC
CFC's contain chlorine fluorine and carbon molecules and are considered the most damaging refrigerants to the stratosphere. They have a very stable chemical structure and a long life when exposed to the atmosphere. This allows them to blow up to the strat
Why are CFC more harmful to the stratosphere than HCFCs because they contain
Hydrogen
true or false . HFCs do not contribute to global warming and do they damage the ozone layer?
true
What is the difference between Azeotropes and near azeotropes
Azeotropes are a blended refrigerants of two or more mixtures. When mixed together they behave like R12 or R22 when phase changing from a liquid to a vapor.
Only one boiling point or one condensing point exists for each given system pressure.
Near- Azeotr
why are there safety precautions for R-410a than with other popular refrigerants like r-22 and r-404a
...
What are the three most popular oils
The three most popular synthetic oils are Polyol ester (POE) Mineral oils and Polyalkylene glycol (PAG) OILs
What is the name of the conference that was held in Canada in 1987 to attempt to solve the problem of refrigerants released into the atmosphere
Montreal Protocol
What agency of government is charged with implementing the US clean air act amendments of 1990?
EPA
What is passive and active recovery
Passive recovery is when the technician uses the internal pressures of the system or the system compressor to aid in that recovery process
Active recovery is when a recovery machine is used.
Are federal excise taxes on reclaimed refrigerants the same as those for new refrigerants?
There is no tax on reclaimed refrigerants, like there are federal takes on new refrigerants.
What is meant to Recover a system
To Recover means to remove refrigerant in any condition from a system and store it in an external container without necessarily testing it or processing it in any way.
What is meant to recycle a system
To Recycle means to clean the refrigerant by oil separation, and single or multiple passes through devices such as replaceable core filter driers witch reduce moisture, acidity and particulate matter.
What is meant to reclaim a system
To reclaim means to process refrigerant to new product specifications by means which may include distillation. It will require chemical analyze of the refrigerant to determine that appropriate product specifications are met. This term usually implies the
What is A non pressurize recovery container
A non pressurize recovery container is a recovery cylinder that must be clean, empty and in a vacuum of about 1000 microns before recovery is started.
What federal agency must approve containers?
Department of transportation
What is a quick Couple or quick Connect ?
A quick Couple or quick Connect is a valve located at the end of a hose that hold the refrigerant in the hose when disconnected to help reduce refrigerant loss.
What is The standard that a refrigerant must meet after it has been reclaimed and can be sold to another customer i?
The standard that a refrigerant must meet after it has been reclaimed and can be sold to another customer is ARI 700
What are Two types of piercing valves and what are the advantages and disadvantages ?
Two types of piercing valves are a gasket type and a solder on type.
The gasket type can be use to quicly pierce a pipe but they should be removed when the service is done because the gasket can leak over time. The solder type is permanently soldered into