Chapter 17 Fire attack and foam

Adding foam concentrate to a fire apparatus tank is called

Batch mixing

Attack lines should be connected to a standpipe system

one floor below the fire floor

Class B foam is used for which type of fire

Flammable liquids

Compared to fog nozzle streams, smooth-bore nozzle streams

absorb less heat

For which preconnected hose load does the fire fighter shoulder part of the load, with hose paying off the top of that load as the fire fighter advances

Minuteman

Generally speaking , a 1 1/2" (38-mm) attack hose can flow

60 to 125 gpm (227 to 473 lpm)

Generally speaking, a 1 3/4" (45-mm) attack hose can flow

120 to 180 gpm (454 to 681 lpm)

Generally speaking, a 1" (25cm) booster hose can flow

40 to 50gpm (151 to 189lpm)

Hard rubber hose stored on a hose reel is __ hose

Booster

How does foam extinguish flammable liquid fires

Separates the fuel from the fire

How should fire fighters space themselves when advancing an uncharged line up a ladder

one fire fighter on each ladder section

In general, what volume does a 2 1/2" (64-mm) handline flow

250gpm (946 lpm)

Master streams flow a minimum of

350gpm (1325lpm)

Most fog nozzles are designed to operate at which nozzle pressure

100 psi (690 kPa)

Most smooth-bore nozzles are designed to operate at which pressure

50 psi(345kPa)

The function of a standpipe system is to provide

a water supply for interior attack lines

The low surface tension of Class A foam affects its extinguishing properties by

enabling water to penetrate the fuel more deeply

To batch mix 3 percent foam into a 500-gallon ( 1893-liter) water tank, how much foam concentrate should be added to the tank

15 gal (57L)

What is a benefit of class A foam

Reduces the surface tension of water

What is an advantage of a fog-stream nozzle

Greater heat absorption per gallon discharged

What is an advantage of a smooth-bore nozzle

Longer stream reach

What is an advantage of an automatic fog nozzle

The flow rate adjust to maintain the rated nozzle pressure

What is an appropriate use for a 1" (25-mm) booster line

Dumpster fire

What is high-expansion foam particularly used for

Flooding of large enclosed areas

What is the correct operating pressure for an in-line foam educator

200 psi (1379kPa)

What is the correct procedure for a burst hose line

Use two lengths of hose to replace a single burst length

What is the correct procedure for deploying a triple-layer load preconnect

Place the nozzle and the top fold over the should and walk away from the apparatus

What is the correct procedure for the triple-layer load

The entire load must be on the ground before the nozzle can be advanced

What is the second stage of advancing an attack line

advancing the line to the point of attack

What is the term for a hose line that is stored on an engine connected to a discharge and equipped with a nozzle for immediate deployment

preconnect

When there is extra hose at the entry of a building , how should that hose be arranged

A serpentine pattern

When using a standpipe connection in a stairwell, how should the hose be arranged

up the stairwell toward the floor above the fire

Which attack line load is often coupled to a larger-diameter line

wyed lines

Which attack line load is particularly useful when the line must be advanced up a stairway

Minuteman

Which attack line load is particularly useful when there is a long distance between the engine and the fire

Wyed lines

Which device mixes foam concentrate in the water stream in the proper percentage

proportioner

Which foam application method is best for a pool of flammable liquid on open ground

Sweep (roll-on)

Which foam application method is best for an open-top storage tank fire

Bankshot( bank-down)

Which hose diameter is used as both supply line and attack handline

2 1/2" (64mm)

Which nozzle type has the highest flow rate

Master stream

Which preconnected hose load forms an S-shape in the hose bed

Triple layer

Which statement about operating a nozzle from a ground ladder is correct

The hose must be tied securely to the ladder

Which statement about straight streams is correct

A straight stream is discharged from an adjustable fog nozzle

Which type of foam contains a surface-active agent that produces a fast-spreading film

Fluoroprotein

Which type of foam is effective on polar solvents

Alcohol-resistant

Which type of foam is made from animal by-products

Protein

Which type of foam is particularly well suited for gasoline spills

Aqueous film-forming

Which type of fog-stream nozzle provides a flow between 90 and 225gpm (340 and 852lpm)

Automatic-adjusting

Which type of hose ranges in size form 1" to 1 1/2" (25 to 38mm) in diameter

Forestry

Which type of hose ranges in size from 2 1/2" (65mm) to 3" (75mm) in diameter

Medium

Which type of load is most commonly used for pre connected attack lines

Minuteman

Which type of nozzle is most commonly used to apply aqueous film-forming foam

Adjustable fog

Which type of nozzle is used most commonly with fluoroprotein foam

Aerating

Which type of nozzle is used to fight fires in inaccessible places such as attics and basements

Cellar