Fire Hose Chapter 15 FF 1 & 2

A hose___ is used to seal small cuts or breaks that may occur in fire hose or to connect mismatched or damaged couplings of the same size to stop leaking.

Jacket

Hose that has come in contact with an acidic chemical should be thoroughly scrubbed

With a solution of backing soda

When the section of hose has burst and no hose clamp is available

Shut off the water by making two bends in the hose

Sexless hose couplings are sometimes referred by their brand name, which is

Storz

If dust and dirt on a woven jacket fire hose cannot be removed by brushing, it should be washed with

Clear water

A hose clamp should be placed a minimum of____feet from fire apparatus

20

A typical siamese appliance will have____connections

2 female 1 male

Appliance needed to combine two hoselines into one hoseline is called

Siamese

A firefighter without a spanner wrench can usually break the tight coupling if the_____method is used

Knee-press

One of the most useful tools to aid in handling a charged hoseline is a hose

Strap

Attack and supply hose may be equipped with what type of couplings?

Threaded and non threaded

Recommended method of drying a hose that has been washed and cleaned?

Use moderate temperature for mechanical drying

To a void sharp bends and kinks during the advancement of a hoseline up a stairway

Lay the hose on the stairs against the outside wall

A distinct advantage of the Minuteman load over the flat load is that

It is designed to be pulled and advanced by one firefighter

When hose has been exposed to small amounts of oil, it should be washed with

Mild soap and detergent

Devices through which water flows, used in conjunction with fire hose, such as a gate valve, are known as

Appliances

A water Thief is considered a

Variation of wye appliances

Systems in highrise buildings that deliver water from the outside up to fire hose outlets on each floor are called

Standpipe

The term reverse lay describes an apparatus that lays out a supply line

From the fire to the water source

Higbee indicator/cut is

Utilized for aligning the male with the female coupling

Standpipe connection is usually located in the____of a multistory building

Stairwell

What is a common use for the hose rope tool?

Securing hose

When advancing dry fire hose up and multisection ladder, firefighters should climb approximately______ ladder sections apart from one another

1

When a hose is being rolled into twin rolls secured together by a portion of hose itself, is called a____roll

Self locking

The_____Method is performed with two firefighters and used for breaking tight couplings without the use of a spanner wrench

Stiff arm

Devices used in conjunction with fire hose through which no water passes are known as

Tools

The two types of couplings are

Threaded or non threaded/Storz

How many female couplings are on a wye hose appliance

1

Where the hose connects to the hydrant and the pumper drives to the fire is a______lay

Forward

The purpose of a hose adapter is to connect two hose sections of

Equal diameter, but differing threads

An advantage of a forward lay is

The pumper is located at the fire with access to additional hose line

1" rubber hose equipped with 1" couplings is commonly called a

Booster hose

The items that make it possible to join two pieces of hose together or break apart two joined pieces of hose in a rapid manner are called

Couplings

How can one firefighter control the large handline for exposure protection

When placed in a larg loop with firefighter at intersection

Siamese appliances equipped with three clappered inlets are called

Manifold

A hose clamp should be placed approximately______from a coupling and on the water supply (incoming) side

Five feet

When loading fire hose, the____ serves to change the direction of the hose and can also change the location of a coupling

Dutchmen

What type of valves are opened or closed by rotating the handle a quarter turn

Butterfly

The main advantage of the donut role is

Both ends are available on the outside roll

Quickest way to move fire hose at ground level is the

Working line drag

Space provided for hose on fire apparatus is generally referred to as the

Hose bed

Hose washing machines are not capable of sufficiently cleaning

Couplings

A______fits between the end of the hose and the coupling and will prevent water seepage around the end of the hose

Gasket

Curved metal frame that fits over the edge of the roof or windowsill is a

A hose roller

One way to identify the physical structure of a male coupling is by the

Lugs and shanks

Primary purpose of a spanner wrench is for use in

Tightening/loosening hose couplings

Which coupling goes on the inside of a straight whose roll

Male

The type of hose roll that is the easiest to work with is the

Straight/storage

Typical length of a single section of 1-3/4 attack line is

50 feet

There are two types of tests for fire hose; service and______testing

Acceptance

Prior to making entry into a structure fire, fire fighters should consider

Reading the smoke conditions and fire behavior

To prevent a pressurized hose from injuring a firefighter, a gate valve should be placed in the line with a___hole drilled in the gate

1/4 inch

When conducting a hose service test, after charging the hoseline with water

Ensure all air has been discharged from the line

To determine whether there is any slippage of couplings when testing hose

Mark the hose by each coupling using a pencil/marker

To prevent injury should the hose fail, a______should be used when testing fire hose

Special in-line gate valve

The maximum length of time that firehose should be used without a service test is

Twelve months

Prior to advancing the hoseline into a burning area, firefighters operating the hose should be____of the door

Crouching or kneeling while positioned to the side

When laying out fire hose to be service tested, test lengths should be no more than

300 feet

When filling a hose line with water for testing, a pump pressure of approximately____psi is maintained

50

A record should be kept on each section of fire hose; information consists of____should be recorded

The date and results of the annual test

After the proper test pressure for fire hose has been reached, the pressure should be maintained for a period of

Three to five minutes

Which National Fire Protection Association (NFPA) standard includes inspection, care and use of fire hose, couplings and nozzles and testing of fire hose?

1962

In high rise firefighting situations, typically the fire attack will be initiated from

One floor below the fire

The type of hose testing conducted by the fire department is called

Service