APU temp high, advisory illuminated
1. Shut down APU immediately
2. Allow to cool for 60 min
3. Check oil level
APU Compartment Fire
1. Confirm presents of fire with fire guard
2. APU fire T-handle - Pull
3. Fire EXT switch - Reserve
4. Portable fire extinguisher - As Required
5. Fuel pump switch - Off
6. APU control switch - off
Engine Abort Start Procedures
1. Engine PCL - Off
2. Ignition switch - Off
3. Starter button (30 sec.) - Press
4. Engine Starter - Disengage
Engine Starter Does Not Drop Out
1. Appropriate PCL - Disengage
2. Start control C/B - Pull
3. Remove air source by securing APU
Internal Engine Fire
1. ENG PCL both - Off
2. Ignition switch - Off
3. Starter button - Press (30 sec./TGT below 300 C)
4. Engine Starter - Disengage
External Engine Fire
1. Confirm presents of fire with fire guard
2. Engine PCL's - Both Off
3. Engine Fire T-handle - Pull
4. Fire EXT switch - Main
5. Portable fire EXT - As Required
Rotor Brake Slip
1. Engine PCL's - Both Off
2. Rotor brake - On (Do not reset rotor brake)
3. Do not restart engines until brake slippage cause has been remedied
NG % required to advance to ground idle
14%
Oil pressure limitation
22%- 55%
Internal engine fire temp
851'C
Shutdown TGT limit
540'C
Minimum NG % to introduce water
24%
Starter duty cycles
2 minuets on ......... 5 minutes off