C. what component is the primary educator
steam jetv #1 outlet
C.FTC that is automatically valve between the condensor & evaporator
Hot Gas Bypass Valve
C.FTC which measures liduid refrigerant temperature leaving the intercooler
liquid temperature transducer in the alley way
C.What device signals high water in the hot well or FTC to warn of high levels in the hot well
High sensor on the side of the hot well
C.Frind the primary steam condensor
surface condensor
C.Locate the component to Service the rupture disk
access valve on pressure relief valve
C.Find the compressor variable guide vanes
Located in the alley you will find the compressor vanes and the inlet actuator it will high lightcas a whole
C.FTC that releases Vaccum on the turbine shut down
Vacuum breaker on top of the turbine
C.What removes heat from the chilled brine that circulates
The Evaporator
C.FTC that is used to add oil to the compressor
oil sevice valve on the sump
C.FTC that automatically fills the cooling towers 1 or 2
Water make up valves
C.FTC that cools the compressor oil
Oil cooler back of compressor
C.FTC used during extreme low load conditions
Hot gas bypass
C.Find the main compressor for condensing stream
surface condenser
C.FTC that regulates the flow to the intercooler
Flash Gas Valve
C.FTC that cools the first stage of the compressor
flash gas vavle/line
C.FTC which gives you evaporator pressure
low pressure transducer
C.Find the oil cooler for the compressor
on the back of the compressor
C.Where is the high pressure cut out
on discharge line
C.FTC that control the flow between intercooler and compressor
Flash Gas Return Valve
C.Where is the overboard valve
below the recirculating valve on the surfacr condensor
C.Find the device thats shuts down the system when the discharge pressure is too high
High pressure cut out
C.FTC that absorbs heat from the chill water brine through the building
Evaporator
C.FTC which performs 1st stage cooling of steam exhaust of the turbine
the surface condenser
C.FTC which cools steam turbine oil
the turbine oil cool next to the steam bypass and below the turbine oil filter
C.FTC which maintains evaporator pressure during low loads
Hot gas bypass
C.FTC PUMP marked 1 which removes water resulting from condensation steam
condensate pump #1
C.Find the high pressure that connects to the recovery unit
Vapor recovery valve
C.FTC that regulates chiller capacity
inlet vanes
C.Find the high side valve piped to the recovery unit
Vapor recovery unit
C.What component on the high side of rhe chillers is connected to the recovery unit
Vapor recovery unit
C.Which component would be considered on the high side of the system
Vapor recovery valve
C.What is the oil temperature of the compressor
oil tem guage
C.FTC that tells the control panel what the compressors discharge is
Dis charge temp
C. Find the temperture of warter leaving the refrigerant condensore
look at the condensor water outlet thermometer
FTC that signals the recirculating valve when the hot well is too low
silver box next to hot well
which component vents steam from the consensor in the event of high steam pressure
Atmospheric valve
Find the component marked 1 to remove consenser steam
condensate pump
What component is used to throttle the condenser
Plug Valve
Find the power line feeding oil heater #1 or #2
Oil Heater Cable Cover
Find The Discharge stop valve for system 1 or 2 Or Suction Service stop valve
Discharge/Suction service valves
Find where you can check the refrigerant charge for system 1 or 2
Sight glass
FTC that reduces capacity for compressor #2 during low loads
Unloader
Identify the compressor on system #1 or #2 to recover from the filter drier
Filter access valve
Which component will stop liquid refrigerant when not powered
Solenoid
Find the high side stop valve of system #2
Discharge service valve
What pressure the compressor before start up
Solenoid valve
Where is the electric heater cable to heat the oil in system #1
oil heater cable
Find the water shut off valve on the chiller suction side of the condensor
Chilled water inlet
Find the expansion valve for compressor #1 system
above the sight glass
Find the suction pressure of condensor pump #2
look at suction guage
Find the condensor throttle valve
it is the plug valve
Find the oil temperature probe on compressor #1
bottom of compressor
FTC that system number 1 or 2 which regulates flow to the evaporator from the compressor
TEV
Ftc used to remotly monitor the compressor in 1 or 2
thermometer
FTC that controls flow from the condensor to the intercooler
hot gas bypass
Find the disconnent for the turbine aux pump or the compressor aux pumo
LOTO
Find the temperature of the steam entering the surface condensor
Steam guage
FTC which slown downthe turbine after shut down
Vaccum Breaker
FTC that allows you to service the rupture disk
Accress relief valve on pressure valve
What component collects condensate after steam condenses
Hotwell
FTC that initally supplies oil pressure to the compressor
Compressor Aux Oil Pump
What Holds a Refrigeration Charge
Receiver
...
...